In order to use these examples you need
to add them to the project "Snap7.PAS"
and also the Snap7.DLL. Wanting the
Snap7.DLL you can also add it in Windows
Sistem. Download Snap7.PAS e Snap7.DLL for Win32 o Snap7.DLL per Win64 |
How to write and read a REAL value with SNAP 7
// ESEMPIO SCRITTO da Mauro Rubinetti
Sito www.delphiruby.net unit Snap7_real; interface uses Windows, Messages, SysUtils, Variants, Classes, Graphics, Controls, Forms, Dialogs, StdCtrls, ExtCtrls, shellapi, snap7; type TForm1 = class(TForm) LOG1: TMemo; Legge_DBREAL: TButton; SCRIVI_REAL: TButton; Edit_DBD12: TEdit; VAL_LETTI: TEdit; Label1: TLabel; CheckBox1: TCheckBox; Label2: TLabel; Label3: TLabel; Shape1: TShape; Shape2: TShape; Edit_DBD16: TEdit; Button1: TButton; Edit_DBD20: TEdit; Label4: TLabel; Label5: TLabel; Label6: TLabel; Label7: TLabel; Label8: TLabel; DBD: TEdit; Label9: TLabel; Label10: TLabel; Shape3: TShape; procedure FormCreate(Sender: TObject); procedure FormDestroy(Sender: TObject); procedure Legge_DBREALClick(Sender: TObject); procedure SCRIVI_REALClick(Sender: TObject); procedure Button1Click(Sender: TObject); procedure Label6Click(Sender: TObject); private { Private declarations } public { Public declarations } end; var Form1: TForm1; PLC1 : TS7Client; implementation {$R *.dfm} // Creo il mio client (PLC1) procedure TForm1.FormCreate(Sender: TObject); begin PLC1:=TS7Client.Create; PLC1.ConnectTo('192.168.0.2',0,2); // indirizzo PLC a cui punto end; // alla chiusura del programma distruggo il client creato. procedure TForm1.FormDestroy(Sender: TObject); begin PLC1.Destroy; end;; procedure TForm1.Legge_DBREALClick(Sender: TObject); var // Creiamo il Buffer della grandezza ottimale es. "packed array[0..15] of Byte // per leggere un real ci voglio 4 byte per cui [0..3] per 2 [0..7] ecc. DatiPLCREAL: packed array[0..15] of single; I: Integer; Errore: Integer; MyReal: single; // max 4 byte N_BYTE: Integer; BYTE_START : Integer; ValoriLETTURA : Integer; begin ValoriLETTURA := strtoint(VAL_LETTI.Text); N_BYTE := ValoriLETTURA * sizeof(single); ValoriLETTURA := ValoriLETTURA-1; // Per il calcolo for / next parto da 0 if not Plc1.Connected then // se il PLC non risponde esco begin showmessage('PLC NON RISPONDE VERIFICARE INDIRIZZO TCP-IP E CHE IL PLC SIA ACCESO') end; BYTE_START := strtoint (DBD.Text); Errore := Plc1.DBRead(1, // Numero della DB BYTE_START, // Da byte della DB partimo a leggere N_BYTE , // Quanti byte vogliamo leggere @DatiPLCREAL); // Array dove voglio mettere i valori letti if Errore <> 0 then begin Log1.Lines.Add(Trim(CliErrorText(Errore))); // Scrive un eventuale errore Exit; end; // scrivo il valore di ogni singolo bytes dei 4 che compongono un real if checkbox1.Checked then begin Log1.Lines.add( 'Informazione su byte letti:'); for I := 0 to N_BYTE -1 do begin Log1.Lines.add('[Byte ' + inttostr(I) + ']: ' + floattostr(DatiPLCREAL[I])); end; end; // Aggiungo al memo i valori convertiti in interi Log1.Lines.add('Valori reali della nostra DB letta:'); for I := 0 to ValoriLETTURA do begin // LEGGIAMO UN VALORE REALE CHE OCCUPA 4 BYTE // UTILIZZIAMO LA FUNZIONE s7.ValReal MyReal:= S7.ValReal[@DatiPLCREAL[I]]; Log1.Lines.add('[DB1.DBD' + inttostr (BYTE_START)+' ]: ' + floattostr(MyReal)); BYTE_START := BYTE_START +4; end; end; ///////////////////////////////////////////////////////////////////////////// // TEST SCRITTURA DI UN REAL //////////////////////////////////////////////////////////////////////////// procedure TForm1.SCRIVI_REALClick(Sender: TObject); var // Creiamo il Buffer della grandezza ottimale es. "packed array[0..15] of Byte DatiPLCREAL: packed array[0..15] of single; MyReal: single; N_Byte_write : Integer; begin if not Plc1.Connected then // se il PLC non risponde esco begin showmessage('PLC NON RISPONDE VERIFICA INDIRIZZO TCP-IP E CHE IL PLC SIA ACCESO') end; MyReal:=StrToFloat(edit_DBD12.Text); // Trasformo in float quanto scritto nella EDIT S7.ValReal[@DatiPLCREAL[0]]:= MyReal; // Metto nell'array il valoire convertito da S7.ValReal N_Byte_write := SizeOf(MyReal); // calcolo la lunghezza dei byte usati (SizeOf di Real = 4) Plc1.DBWrite(1, // Numero della DB da scrivere 12, // Da quale byte della DB partimo a leggere N_Byte_write, // Quanti byte vogliamo scrivere (REAL = 4) @DatiPLCREAL[0]); // Array dove voglio mettere i valori letti // PLC1.DBWrite(1,12,N_Byte_write,@DatiPLCREAL[0]);// per scrivere un real N_BYTE_WRITE =4 end; ///////////////////////////////////////////////////////////////////////////// // TEST SCRITTURA DI 2 REAL //////////////////////////////////////////////////////////////////////////// procedure TForm1.Button1Click(Sender: TObject); var DatiPLCREAL: packed array[0..15] of single; MyReal1, MyReal2: single; N_Byte_write : Integer; begin if not Plc1.Connected then // se il PLC non risponde esco begin showmessage('PLC NON RISPONDE VERIFICA INDIRIZZO TCP-IP E CHE IL PLC SIA ACCESO') end; MyReal1:=StrToFloat(edit_DBD16.Text); MyReal2:=StrToFloat(edit_DBD20.Text); S7.ValReal[@DatiPLCREAL[0]]:= MyReal1; S7.ValReal[@DatiPLCREAL[1]]:= MyReal2; N_Byte_write := SizeOf(MyReal1); // calcolo la lunghezza dei byte usati PLC1.DBWrite(1,16,N_Byte_write,@DatiPLCREAL[0]);// per scriver un real N_BYTE_WRITE =4 PLC1.DBWrite(1,20,N_Byte_write,@DatiPLCREAL[1]);// per scriver un real N_BYTE_WRITE =4 // con una funzione FOR / NEXT posso scrivere quanti valori voglio end; end. |
How to write and read a DINT value with SNAP 7
// ESEMPIO IN Delphi scritto da Mauro
Rubinetti // www.delphiruby.net unit Snap7_dint; interface uses Windows, Messages, SysUtils, Variants, Classes, Graphics, Controls, Forms, Dialogs, StdCtrls, ExtCtrls, shellapi, snap7; type TForm1 = class(TForm) LOG1: TMemo; Legge_DBREAL: TButton; SCRIVI_REAL: TButton; Edit_DBD0: TEdit; VAL_LETTI: TEdit; Label1: TLabel; CheckBox1: TCheckBox; Label2: TLabel; Label3: TLabel; Shape1: TShape; Shape2: TShape; Edit_DBD4: TEdit; Button1: TButton; Edit_DBD8: TEdit; Label4: TLabel; Label5: TLabel; Label6: TLabel; Label7: TLabel; Label8: TLabel; DBD: TEdit; Label9: TLabel; Shape3: TShape; Label10: TLabel; procedure FormCreate(Sender: TObject); procedure FormDestroy(Sender: TObject); procedure Legge_DBREALClick(Sender: TObject); procedure SCRIVI_REALClick(Sender: TObject); procedure Button1Click(Sender: TObject); procedure Label6Click(Sender: TObject); private { Private declarations } public { Public declarations } end; var Form1: TForm1; PLC1 : TS7Client; implementation {$R *.dfm} // Creo il mio client (PLC1) procedure TForm1.FormCreate(Sender: TObject); begin PLC1:=TS7Client.Create; PLC1.ConnectTo('192.168.0.2',0,2); // indirizzo PLC a cui punto end; // alla chiusura del programma distruggo il client creato. procedure TForm1.FormDestroy(Sender: TObject); begin PLC1.Destroy; end; procedure TForm1.Legge_DBREALClick(Sender: TObject); var // Creiamo il Buffer della grandezza ottimale es. "packed array[0..15] of Byte // per leggere un real ci voglio 4 byte per cui [0..3] per 2 [0..7] ecc. DatiPLCDINT: packed array[0..10] of single; I: Integer; Errore: Integer; MyDint: single; // max 4 byte N_BYTE: Integer; BYTE_START : Integer; ValoriLETTURA : Integer; begin ValoriLETTURA := strtoint(VAL_LETTI.Text); N_BYTE := ValoriLETTURA * sizeof(single); ValoriLETTURA := ValoriLETTURA-1; // Per il calcolo for / next parto da 0 if not Plc1.Connected then // se il PLC non risponde esco begin showmessage('PLC NON RISPONDE VERIFICARE INDIRIZZO TCP-IP E CHE IL PLC SIA ACCESO') end; BYTE_START := strtoint (DBD.Text); Errore := Plc1.DBRead(2, // Numero della DB BYTE_START, // Da byte della DB partimo a leggere N_BYTE , // Quanti byte vogliamo leggere @DatiPLCDINT); // Array dove voglio mettere i valori letti if Errore <> 0 then begin Log1.Lines.Add(Trim(CliErrorText(Errore))); // Scrive un eventuale errore Exit; end; // scrivo il valore di ogni singolo bytes dei 4 che compongono un real if checkbox1.Checked then begin Log1.Lines.add( 'Informazione su byte letti:'); for I := 0 to N_BYTE -1 do begin Log1.Lines.add('[Byte ' + inttostr(I) + ']: ' + floattostr(DatiPLCDINT[I])); end; end; // Aggiungo al memo i valori convertiti in interi Log1.Lines.add('Valori reali della nostra DB letta:'); for I := 0 to ValoriLETTURA do begin // LEGGIAMO UN VALORE INTERO CHE OCCUPA 4 BYTE // UTILIZZIAMO LA FUNZIONE s7.ValDint MyDint:= S7.ValDInt[@DatiPLCDINT[I]]; Log1.Lines.add('[DB1.DBD' + inttostr (BYTE_START)+' ]: ' + floattostr(MyDint)); BYTE_START := BYTE_START +4; end; end; ///////////////////////////////////////////////////////////////////////////// // TEST SCRITTURA DI UN DINT //////////////////////////////////////////////////////////////////////////// procedure TForm1.SCRIVI_REALClick(Sender: TObject); var // Creiamo il Buffer della grandezza ottimale es. "packed array[0..15] of Byte DatiPLCDINT: packed array[0..15] of single; MyDint: Longint; N_Byte_write : Integer; begin if not Plc1.Connected then // se il PLC non risponde esco begin showmessage('PLC NON RISPONDE VERIFICA INDIRIZZO TCP-IP E CHE IL PLC SIA ACCESO') end; MyDint:=StrToInt(edit_DBD0.Text); // Trasformo in float quanto scritto nella EDIT S7.ValDint[@DatiPLCDINT[0]]:= MyDint; // Metto nell'array il valoire convertito da S7.ValReal N_Byte_write := SizeOf(MyDint); // calcolo la lunghezza dei byte usati (SizeOf di Real = 4) Plc1.DBWrite(2, // Numero della DB da scrivere 0, // Da quale byte della DB partimo a leggere N_Byte_write, // Quanti byte vogliamo scrivere (REAL = 4) @DatiPLCDINT[0]); // Array dove voglio mettere i valori letti // PLC1.DBWrite(1,12,N_Byte_write,@DatiPLCREAL[0]);// per scrivere un real N_BYTE_WRITE =4 end; ///////////////////////////////////////////////////////////////////////////// // TEST SCRITTURA DI 2 DINT //////////////////////////////////////////////////////////////////////////// procedure TForm1.Button1Click(Sender: TObject); var DatiPLCDINT: packed array[0..15] of single; MyDint1, MyDint2: Int64; N_Byte_write : Integer; begin if not Plc1.Connected then // se il PLC non risponde esco begin showmessage('PLC NON RISPONDE VERIFICA INDIRIZZO TCP-IP E CHE IL PLC SIA ACCESO') end; MyDint1:=StrToInt64(edit_DBD4.Text); MyDint2:=StrToInt64(edit_DBD8.Text); S7.ValDint[@DatiPLCDINT[0]]:= MyDint1; S7.ValDint[@DatiPLCDINT[1]]:= MyDint2; N_Byte_write := SizeOf(MyDint1); // calcolo la lunghezza dei byte usati PLC1.DBWrite(2,4,N_Byte_write,@DatiPLCDINT[0]);// per scriver un real N_BYTE_WRITE =4 PLC1.DBWrite(2,8,N_Byte_write,@DatiPLCDINT[1]);// per scriver un real N_BYTE_WRITE =4 // con una funzione FOR / NEXT posso scrivere quanti valori voglio end; end. |
Demo to test the potential of SNAP 7
|
Download and
test this little program written in Delphi
to test the performance of the SNAP 7
library. It could be useful to make readings
of any Siemens S7 300/400 PLC or to
communicate with some Siemens 1200 or 1500
PLC and then the data, if desired you can
save them.. DOWNLOAD THE PROGRAM Remember to also download the SNAP7.dll 32 or 64 bit version depending on your operating system and copy it to the test program folder or copy it to windows / system32. Note: To be able to read a DB from a Siemens 1200 or 1500 PLC with SNAP 7, the DB must not be "optimized" and must have enabled the check that allows "GET" and "PUT" |